Background: The SMARTLock Hybrid MMF System from Stryker is a newer approach for maxillomandibular fixation. ). This innovative system accommodates all mandibular fracture and reconstruction needs in one small, simple and . Unit price / per . More payment options. Zimmer Biomet is a leader in Craniomaxillofacial surgical solutions. Pectus Excavatum, Pectus Carinatum, and other chest wall deformities. "Evaluation of Hardware-Related Complications in Vascularized Bone Grafts with Locking Mandibular . Subsequently, smaller screws (2.0 mm) are effective for simple fractures, and screws of larger diameters (2.3 mm) are better suited for comminuted or multiple fractures. et al. Standard mandibular reconstruction plates ( N = 7, 2.8 mm profile height, bar widths of 5.5 mm at angle and 4.3 mm elsewhere, Ref. This software, designed for the Stryker Navigation System, allows surgeons to employ image-guided surgery in conjunction with intraoperative fluoroscopic images. 1 at other centers, however, mandible fractures play less of a prominent role and have accounted Code Information: Lot J8100F1669. Customizable Design Features Recon Plate, Straight, w. Template, Stryker Leibinger GmbH & Co., Freiburg, Germany; REF # 55-28911. A more rigid variant, which is more like an arch bar screwed into the bone, may offer . Rehabilitation and reconstruction of the oral cavity following the resection of pathologic processes remains a complex challenge. Non-clinical testing and analysis have demonstrated that when used in peripheral vasculature Stryker Detachable Coils are MR Conditional. Orthognathic surgery (surgical correction of dentofacial deformities) 094734-180709. Jewer et al. We use cookies to customize content for your viewing and for analytics. The Stryker Universal CMF System was cleared in K022185 and serves as the Reference Device for the Subject Device, as the Subject Device performance testing is in comparison to this Reference Device to make a substantial equivalence determination. - Same Mode of Fixation: fixated to the native bone with Stryker rbable Delta Reso The Stryker mandibular plating system has 2.0-, 2.3-, and 2.7-mm screws that can be used in any one of their plates (miniplates, recon plates, etc. All patients who were treated with a 2.0-mm locking bone plate/screw system during an 8-month period for fractures of the mandible or other defects of the mandible were prospectively studied. Mandible Plating System. Stryker is one of the preeminent medical products and services companies in the world. In 2002, the Company launched the Universal Mandible Plating System. mandible), whereas you will use 802.3x (Open fracture of mandible) for open fractures of the lower jaw. Rigid internal fixation for primary and secondary mandible reconstruction. After proper reduction of angle fracture, fixation was carried out using a 1.7 mm 10-hole titanium straight 3D strut plate (Stryker-Leibenger, Freiburg, Germany). Reconstructive surgery. Trade/Device Name: Stryker Surgeon iD Mandible Recon Plate Regulation Number: 21 CFR 872.4760 Regulation Name: Bone Plate Regulatory Class: Class II Product Code: JEY Dated: May 29, 2019 . Stryker Corp. Monday announced the global commercial launch of the Universal SmartLock Hybrid maxillomandibular fixation (MMF) system. Synthes Mandibular Modular Fixation System Plates Catalog # Description 310.562 1.8 mm Bit Stryker J-Latch, 75 mm 310.512 1.8 mm Drill Bit Stryker J-Latch, 100 mm (2) 449.24 2.4 mm Titanium LC-DCP Plate Crescent 4 Holes, 35 mm (2) 449.234 2.4 mm Titanium LC-DCP Eccentric Plate, 4 Holes 449.14 2.4 mm Titanium LC-DCP Plate, 4 Holes, 35 mm (2) Universal 2 CMF Plating Overview The Universal 2 System is a comprehensive craniomaxillofacial titanium plating system, and includes a wide selection of high quality implants for bone fixation of craniomaxillofacial fractures, orthognathic and reconstructive surgery. . Our Mandible portfolio includes clinically proven titanium, and MEDPOR implants, Virtual surgical planning and medical models, a patient specific Customized Mandible Reconstruction plate, MEDPOR customized facial implant, as well as the market leading electrosurgical needle, the Colorado Needle. The Profyle Modular Hand Plating System, launched in 2002, features simple instrumentation, low-profile implants and a wide variety of screw diameters and plate configurations. If you continue to browse this website, we will assume that you are happy to receive all our cookies. Miniplate System- Case: 914-920. This study was performed to determine the clinical application, complications, radiographic findings, and cost effectiveness of the SMARTLock system. Imaging confirmed fractures and showed mandible thickness greater than 20 millimeters. The Stryker was conceived as a family of vehicles forming the backbone of a new . The investigators hypothesized differences in maximum mechanical stress forces and deflection with each plating material; however, it was proposed that the experimental forces withstood by the resorbable system would be enough to withstand normal forces . intended for use in the mandible and/or full load bearing procedures. PLATING SYSTEM Streamlined set for craniofacial and mandibular trauma and reconstruction. mandibular and maxillary fractures in adults and adolescents (age 12 and higher) in whom permanent teeth have erupted. The Stryker Universal Mandible System is intended for stabilization and rigid fixation of This study was performed to determine the clinical application, complications, radiographic findings, and cost effectiveness of the SMARTLock system. A spanning reconstruction plate between the inferior borders of the mandibular body positions the long axis of the plate parallel with the splaying forces on the mandible. Stryker; Karl Storz; Medtronic; Arthrex; Buy Medical Equipment; Sell Medical Equipment . Purpose . The Stryker is a family of eight-wheeled armored fighting vehicles derived from the Canadian LAV III.Stryker vehicles are produced by General Dynamics Land Systems-Canada (GDLS-C) for the United States Army in a plant in London, Ontario.It has four-wheel drive (84) and can be switched to all-wheel drive (88). Mandibular Plate System- Case: 914-926. Our focus is on the fundamentals and a relentless attention to details of not only design and manufacture, but also of application and outcomes. DePuy Synthes MatrixRIB straight plates are indicated for . Synthes Mandibular Modular Fixation System Plates Catalog # Description 310.562 1.8 mm Bit Stryker J-Latch, 75 mm 310.512 1.8 mm Drill Bit Stryker J-Latch, 100 mm (2) 449.24 2.4 mm Titanium LC-DCP Plate Crescent 4 Holes, 35 mm (2) 449.234 2.4 mm Titanium LC-DCP Eccentric Plate, 4 Holes 449.14 2.4 mm Titanium LC-DCP Plate, 4 Holes, 35 mm (2) Plate design is based upon a CT scan of the patient. Craniomaxillofacial Surgical Planning. CONTRAINDICATIONS Non-reducible and unstable fractures (except reconstruction plates). Abstract Background: The SMARTLock Hybrid MMF System from Stryker is a newer approach for maxillomandibular fixation. . ZIMMER Biomet Mandibular Plate Systems dental osteosynthesis maxillofacial. Materials and Methods . . 4 Synthes MatrixCOMBO Plating Set Instrument Tray for Mandible Instruments (60.511.103) From a 2.0 mandible plate, cut pieces of 2-hole length for the maxilla and 3-hole length for the mandible. DePuy Synthes MatrixRIB precontoured plates are indicated for the fixation, stabilization and reconstruction of: Rib fractures, fusions, osteotomies, and/or resections, including spanning gaps and/or defects. The orientation of the scalpel blade must be parallel to the relaxed skin tension lines (RSTL). Make an offer. The Stryker CMF Customized Implant Team creates a virtual mandible reconstruction and an individual plate design with optional online participation of the surgeon. Plate is designed using patient specific CT data and is delivered pre formed to match the planned design to the patients anatomy. The output of our work supports the skills and talents of the medical profession. To our knowledge, ours is the first report on the clinical use of a different 3D miniplate of the Universal Mandibular Plating System (Stryker/Leibinger, Freiburg, Germany). The Universal Select system is a comprehensive Craniomaxillofacial titanium plating system, which includes a wide selection of implants for bone fixation of Craniomaxillofacial fractures, orthognathic and reconstructive surgery. However, it has been our preference to use high-profile LMRPs for vascularized bone graft fixation because they are more rigid and less prone to deformation during insetting . . Continuity defects of the jaw can be reconstructed with titanium plates or microvascular bone flaps; osteosynthesis plates are necessary for both. The Leibinger Locking System (Stryker Leibinger Inc, Kalamazoo, Mich) MRP was used to bridge the segmental mandibular defects in all cases. Indications for Use. et al. This system offers excellent flexibility in the placement of the screws. The maxillomandibular fixation (MMF) device combines elements of both arch bars and MMF screws, stated the company announcement. Five unaltered synthetic mandibles were used as controls. ZIMMER Biomet Mandibular Plate . Stryker is one of the world's leading medical technology companies and, together with our customers, we are driven to make healthcare better. The MRPs were applied to the buccal cortex of the remaining native mandible using standard techniques. The Synthes MatrixMIDFACE Plating System is intended for use in selective trauma of the midface and craniofacial . Indication Statement. We deliver a wide array of devices focused on helping surgeons in treating the cranium, mandibular and maxillofacial skeleton. A more rigid variant, which is more like an arch bar screwed into the bone, may offer . 3D Systems' VSP surgical planning solutions for craniomaxillofacial (CMF) applications received FDA clearance as a service-based approach to personalized surgery over 10 years ago. When fractures occur, they have the ability to affect the patient's occlusion significantly, cause infection, and lead to . Biomechanical Evaluation of a Mandibular Spanning Plate Technique Compared to Standard Plating Techniques to Treat Mandibular Symphyseal Fractures MatthewRichardson, 1 JonathanHayes, 1 J.RandallJordan, 1 AaronPuckett, 2 andMatthewFort 1 University of Mississippi Medical Center, Department of Otolaryngology and Communicative Sciences, 317.72 1.5 mm Drill Bit, Stryker J-Latch, . Mller, M. Allgwer, R. Schneider, and H. Willenegger: . OR. According to the AO, internal xation is distinguished by precise reduction, stable xation, preservation of blood supply, and early, functional mobilization. The Stryker was conceived as a family of vehicles forming the backbone of a new . The Stryker is a family of eight-wheeled armored fighting vehicles derived from the Canadian LAV III.Stryker vehicles are produced by General Dynamics Land Systems-Canada (GDLS-C) for the United States Army in a plant in London, Ontario.It has four-wheel drive (84) and can be switched to all-wheel drive (88). Treatment for mandibular fractures is commonly performed via open reduction fixation with mini titanium or resorbable plates and screws. Our portfolio encompasses a number of essentials for CMF surgery including implants, instruments, e-tools and specialized patient-matched services to . The mandible assists in verbalization, oral competence,. Legacy meets flexibility Overview The Universal Select system is a comprehensive Craniomaxillofacial titanium plating system, which includes a wide selection of high quality implants for bone fixation of Craniomaxillofacial fractures, orthognathic and reconstructive surgery. Features and benefits Anchor screw Designed to minimize patient trauma and provide quick removal. M.E. ZIMMER Various Plate Systems- Lot of 4 Good Condition. MATRIXCOMBO PLATING SET Mandible Instrument Tray MatrixMIDFACE Trauma Module MatrixMANDIBLE Trauma Module 1. 1.2/1.7mm AXS screws 1.2/1.7mm AXS screws The Universal Select system is a comprehensive Craniomaxillofacial titanium plating system, which includes a wide selection of implants for bone fixation of Craniomaxillofacial fractures, orthognathic and reconstructive surgery. 317.72 1.5 mm Drill Bit, Stryker J-Latch, The purpose of this study is to compare the biomechanical behavior of the spanning reconstruction plate compared to standard plating techniques for mandibular symphyseal fractures. It covers the entire range for trauma, orthognathic and reconstructive indications. Both previous studies on the use of the curved 2 mm angle strut plate for angular fracture treatment 14 , 15 reported low complication rates and concluded that the 3D plate . OP-1 After proper reduction of angle fracture, fixation was carried out using a 1.7 mm 10-hole titanium straight 3D strut plate (Stryker-Leibenger, Freiburg, Germany). Stryker Pediatric Mandible Distractorastryker Device Description: The Pediatric Mandible Distractor (PMD) System is a distraction system consisting of the following major components: distractor. Stryker J-Latch, 8 mm stop, 2 ea. Vendor Kinamed Regular price Sold out Sale price Sale. The matrix wave plate is a bone-anchored intermaxillary fixation system. While miniplate fixation and an intra-oral approach is . Careers; used a classification system designed to reflect the complexity of the reconstruction. Mller, M. Allgwer, R. Schneider, and H. Willenegger: . Mark the incision site and make a small stab incision to prepare for the insertion of the cannula. The MatrixMANDIBLE plate and screw system is intended for oral, maxillofacial surgery: Trauma. The Jewer classification provides an aid in classifying mandibular . Common or Usual Name: Resorbable Bone Plating System Device: Stryker Resorbable Fixation System Classification Name & Regulation Description: Plate, Fixation, Bone; per 21 CFR 888.3030 . . The Company offers a diverse array of innovative products and services in Orthopaedics, Medical and Surgical, and Neurotechnology and Spine that help improve patient and hospital outcomes. The plating system used in our series (Leibinger Universal Mandibular System, Stryker-Craniomaxillofacial) also includes a low-profile LMRP with a profile height of 1.5 mm. Spatial gradient field up to 2500 Gauss/cm (25 Tesla/m) Universal Select plating system Customized cranial implants Product portfolio Universal CMF titanium plating Universal neuro titanium plating MEDPOR porous polyethylene implants Customized cranial implants Customized midface and mandible plating Hybrid MMF Hydroxyapatite bone cements Delta Resorbable Implants Precontoured reconstruction plates with profile heights of 1.5 mm and 2.8 mm Plates accommodate multiple screw types and diameters Compatibility of plates and screws within modules Cross Pin screw head design that combines the advantages of friction fit, axial guidance and torque transmission Sterile implants It was positioned on the lateral surface of the mandible with the struts paralleling the fracture line. PLATING SYSTEM Streamlined set for craniofacial and mandibular trauma and reconstruction. The location is predetermined by palpation. No. This system is designed for use as an anchor in orthodontic procedures such as intrusion/extrusion of teeth, space closure, distal/mesial movement, and 3D control of teeth. Subsequently, smaller screws (2.0 mm) are effective for simple fractures, and screws of larger diameters (2.3 mm) are better suited for comminuted or multiple fractures. It was positioned on the lateral surface of the mandible with the struts paralleling the fracture line. Micro/Miniplate Cassette - Case: 914-930. With nine potential points of fixation along the plate . Purpose: To compare the initial stability and stability after fatigue of three different locking systems (Synthes(), Stryker() and Medartis()) for mandibular fixation and reconstruction. Device Description: The Stryker Universal SMARTLock Hybrid MMF System is a maxillomandibular fixation system that consists of a pure titanium fixation Plate, 2 self-drilling locking Screws made KINAMED NEURO PRO RIGID FIXATION SYSTEM CRANIAL PLATING TITANIUM SET 2. K132519, Stryker Customized Mandible Recon Plate Kit Bar width increase Pearls of Mandibular Trauma Management John C. Koshy, M.D.,1 Evan M. Feldman, M.D.,1 Chuma J. Chike-Obi, M.D.,1 and Jamal M. Bullocks, M.D.1 ABSTRACT Mandibular trauma is a common problem seen by plastic surgeons. This innovative system accommodates all mandibular fracture and reconstruction needs in one small, simple and easy-to-use system. Place the index finger over the desired osteosynthesis site and match it with the thumb on the cheek surface. "Evaluation of Hardware-Related Complications in Vascularized Bone Grafts with Locking Mandibular . A patient can be safely scanned immediately after placement of the coils, under the following conditions: Static magnetic field of 1.5 and 3.0 Tesla. 1.2 Upperface Plating Module 1.7 Midface Plating Module 2.0 Mini Plating Module mandibular angle (long arrow) fractures Note involvement of left mental foramen On post-injury day three, the patient went to the operating room for open reduction and internal fixation with 2.3 mm miniplates using the Stryker Universal Mandible plating system (Stryker, Kalamazoo, USA). Stryker J-Latch, 8 mm stop, 2 ea. A mandibular plate and screw system intended for stabilization and rigid fixation of mandibular fractures and reconstruction. Introduction The aim of surgical fracture treatment is to reconstruct the bony anatomy and restore its function. Stryker Corporation has launched the Universal SMARTLock Hybrid MMF System invented by Jeffrey Marcus, M.D., Associate Vice-Chair of Surgery at Duke University. The matrix wave plate is a bone-anchored intermaxillary fixation system. Four experimental groups of different reconstruction techniques with five in . Customizable design Proprietary software to select specific plate design features such as profile height, screw hole location, and 3D run of the plate. In Twenty-five human mandible replicas were used. The patient was treated by open reduction internal fixation with miniplates via an intra-oral approach and recovered without deficit. Microplate System- Case: 914-380. 3D Systems and Stryker Corporation have partnered to provide surgeons with best-in-class products and services for . M.E. Leibinger Universal CMF Plating System The Leibinger Universal CMF System is a craniomaxilllofacial plate and screw system intended for osteotomy, stabilization and rigid fixation of CMF fractures and reconstruction. A 70-year-old edentulous male presented with bilateral mandible and left midface fractures following an assault. This offers a theoretical mechanical advantage, but the biomechanical behavior of the spanning reconstruction plate used in conjunction with two parallel plates' system has . . Adding product to your cart. . 55-28922, grade 2 titanium, Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) were bent into shape by two experienced surgeons. Depending on the site of fracture, you will have to use a 5th digit expansion to 802.2x and 802.3x. Universal Mandible System: The Stryker Leibinger New Generation / Universal Mandible System is a mandibular plate and screw system intended for stabilization and rigid fixation of mandibular fractures and mandibular reconstruction. For example, if you are reporting an closed fracture of the alveolar ridge of the mandible, you will have to report 802.27 (Closed fracture of the Stryker Universal CMF System. To compare the initial stability and stability after fatigue of three different locking systems (Synthes, Stryker and Medartis) for mandibular fixa View More. Anchor plate Stryker J-Latch, 75 mm 311.006 Screwdriver Handle, with hex coupling, medium, 2 ea. mandibular fractures play a significant role in craniofacial trauma and have accounted for nearly 50% of the facial fractures that we have encountered at the texas medical center, thus making it the most commonly fractured facial bone at our center. Mandibular defects can generally be considered by their location and extent and can be divided into defects involving the anterior mandible, lateral mandible, and ramus/condyle. This system offers excellent flexibility in the placement of the screws. ). From a 2.0 mandible plate, cut pieces of 2-hole length for the maxilla and 3-hole length for the mandible. The Stryker mandibular plating system has 2.0-, 2.3-, and 2.7-mm screws that can be used in any one of their plates (miniplates, recon plates, etc. K014263, Stryker Universal Mandible System. Recalling Firm/ Manufacturer: Stryker Leibinger USA 750 Trade Center Way Ste 200 For further information please read our cookie policy. MATRIXCOMBO PLATING SET Mandible Instrument Tray MatrixMIDFACE Trauma Module MatrixMANDIBLE Trauma Module 1. Method: Standard mandible locking plates with identical profile height (1,5 mm), comparable length and screws with identical diameter (2,0 mm) were used. 7 English.

stryker mandibular plating system 2022